Acta IMEKO https://acta.imeko.info/index.php/acta-imeko <p>The online journal of IMEKO - the <a href="https://www.imeko.org">International Measurement Confederation</a>.</p> IMEKO en-US Acta IMEKO 0237-028X <p><strong>Authors</strong> retain copyright and grant the journal right of first publication with the work simultaneously licensed under the <span class="alt-titles"><span class="tool-identifier">CC BY 4.0,</span></span> <a href="http://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution 4.0 International License</a>.</p> <p><strong>Users</strong> are free to</p> <ul> <li>share, i.e. copy and redistribute the material in any medium or format for any purpose, even commercially;</li> <li>adapt, i.e. remix, transform, and build upon the material for any purpose, even commercially.</li> </ul> <p>At the same time, the <strong>user</strong> must give appropriate credit, provide a link to the license, and indicate if changes were made. <br />Additional information about the license can be found at: <a href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</a>.</p> <p><strong>Authors</strong> are</p> <ul> <li>able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.</li> <li>permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See <a href="http://opcit.eprints.org/oacitation-biblio.html" target="_new">The Effect of Open Access</a>).</li> </ul> Characterization of a liquid bath for accurate thermometer calibration and detailed uncertainty estimation https://acta.imeko.info/index.php/acta-imeko/article/view/2191 <p>The reliable characterization of liquid baths is essential for ensuring traceable and accurate temperature calibrations in metrology laboratories. In this study, a liquid water bath with a copper equalizing block of 12 cm length was characterized at three calibration points of 5 °C, 29.7 °C, and 80 °C. The bath performance was assessed through drift evaluation, stability, axial and radial uniformity, and loading influence using two 25 Ohm (Ω) standard platinum resistance thermometers (SPRTs). The results obtained showed excellent drift performance within ± 1 millikelvins (mK) over 12 hours at 20 °C. The instability at the three calibration points remained below 1 mK. Axial and radial uniformity values did not exceed 0.9 m 2.7 mK, respectively, and the loading effect produced temperature deviations of less than 3 mK. A detailed uncertainty analysis was carried out based on the requirements of the <em>Guide to the expression of uncertainty in measurement</em> (ISO GUM), considering all relevant contributions from the SPRTs and the liquid bath. The combined standard uncertainties of the bath characterization were 2.70, 3.17, and 3.87 mK at 5 °C, 29.7 °C, and 80 °C, respectively, all well below the 10 mK benchmark typically required for precision calibration baths. After the liquid bath characterization, calibration of a platinum resistance thermometer (PRT) by comparison against a 100-Ω SPRT was performed at 5 °C, 29.7 °C, and 80 °C. The associated expanded uncertainties of calibration were 0.052 °C, 0.050 °C, and 0.043 °C, respectively, including the bath characterization uncertainty. These findings confirm that the characterized liquid bath provides a stable and homogeneous thermal environment suitable for high-accuracy thermometer calibrations.</p> Oqab AlOtaibi Ismail A. AlFaleh Adel B. Shehata Copyright (c) 2026 Oqab AlOtaibi , Ismail A. AlFaleh, Adel B. Shehata https://creativecommons.org/licenses/by/4.0 2026-11-17 2026-11-17 15 4 1 11 10.21014/actaimeko.v15i4.2191 Quantitative physical metrology for testing historical hypotheses: Fortified and religious networks in Southern Italy during the Longobard–Norman transition https://acta.imeko.info/index.php/acta-imeko/article/view/2381 <p>This paper tests a historical hypothesis concerning the evolution of Norman territorial control in Southern Italy through a quantitative physical metrology procedure based on acoustic and cartographic criteria. The study compares two territorial configurations: the current province of Potenza (Basilicata region), and the provinces of Salerno and Avellino (Campania region). A validated georeferenced database of medieval military and religious sites was used to analyse fortified, monastic and ecclesiastical nodes in relation to acoustic reachability, intervisibility, proximity to historical routes and network continuity. Bell sound was treated as both an intangible heritage element and a measurable physical signal. A frequency-dependent attenuation model, based on geometrical spreading and atmospheric absorption, was used to define an operational audibility radius for potential bell-based communication, subsequently integrated with GIS-based spatial computation. Results show that, in Basilicata, the limited number of intervisible and acoustically reachable relations, together with the proximity of fortifications to Roman road corridors, supports a model based mainly on local defensive control and route supervision. In Campania, instead, the spatial integration between defensive and religious sites appears more compatible with a potential acoustic communication network, suggesting a more structured territorial system. The study demonstrates that physical metrology can act as a hypothesis-testing framework in historical and archaeological research, allowing intangible communication phenomena to be investigated through measurable physical and spatial constraints</p> Marco Casazza Rosa Fiorillo Fabrizio Barone Copyright (c) 2026 Marco Casazza, Rosa Fiorillo, Fabrizio Barone https://creativecommons.org/licenses/by/4.0 15 4 1 17 10.21014/actaimeko.v15i4.2381 Finite element modeling of a nominal tetrachiral lattice under quasi-static compression with preliminary insights into manufacturing-induced geometric deviations https://acta.imeko.info/index.php/acta-imeko/article/view/2475 <p>This study presents the finite element modeling of an SLA-manufactured tetrachiral lattice subjected to quasi-static uniaxial compression. The constitutive law of the base material was calibrated using cyclic compression tests performed on bulk specimens, providing the elastic modulus, yield stress, and true-stress--plastic-strain relationship. A three-dimensional finite element model of the nominal lattice geometry was developed in Abaqus and solved using the explicit solution scheme. The numerical predictions showed good agreement with the experimental force–displacement response during the initial stage of compression. However, the numerical model progressively overestimated the load-carrying capacity as the deformation increased. Preliminary comparison of the nominal CAD geometry with X-ray computed tomography (XCT) data revealed manufacturing-induced geometric deviations, that may contribute to the discrepancies between the numerical and experimental responses. These findings highlight the need for a finite element framework that incorporates as-manufactured geometries and representative boundary conditions derived from full-field measurements obtained using Digital Volume Correlation (DVC).</p> Vito Topić Brečević Emina Hadzalic Veronika Drechslerová Petr Koudelka Daniel Kytýř Zvonimir Tomičević Copyright (c) 2026 Vito Topić Brečević, Emina Hadzalic, Veronika Drechslerová, Petr Koudelka, Daniel Kytýř, Zvonimir Tomičević https://creativecommons.org/licenses/by/4.0 2026-11-17 2026-11-17 15 4 1 8 10.21014/actaimeko.v15i4.2475 Comparison of fracture energy of concrete under static and cyclic loading https://acta.imeko.info/index.php/acta-imeko/article/view/2505 <p>Fracture energy is the primary input for any cohesive analysis of concrete, yet it is almost always measured under monotonic static loading, while real structures are loaded repeatedly. This paper compares the fracture energy obtained from static three-point bending of notched concrete beams with the value derived from the envelope of low-cycle tests on nominally identical specimens of the same mix. Beams with relative notch depths <em>a</em>/<em>W</em> = 0.3 were tested on a servo-hydraulic machine, with the crack mouth opening displacement (CMOD) measured by a clip extensometer. The static work of fracture reached 258 J/m² up to a common CMOD of 0.42 mm, against 249 J/m² for the two low-cycle specimens, a difference of 3.4 %. The damage obtained from the unloading stiffness exceeded 0.9 by a CMOD of approximately 0.2 mm, while the irreversible CMOD grew linearly with CMOD at a slope of 0.88 to 0.92.</p> Petr Miarka Kamila Kozakova Lucie Malíková Vlastimil Bílek Copyright (c) 2026 Petr Miarka, Kamila Kozakova, Lucie Malíková, Vlastimil Bílek https://creativecommons.org/licenses/by/4.0 2026-11-17 2026-11-17 15 4 1 7 10.21014/actaimeko.v15i4.2505